Arrakis Systems MARC-15 Manual Page 55

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 54
I N S TA L L A TI O N I N S T R U C TI O N S
4.27
1
2
3
4
5
6
7
8
Talk
Tally
Channel Off
Ground
Channel On
Cough
nc
nc
Logic
1
2
3
4
5
6
7
8
(+) in
(-) in
nc
Ground
nc
nc
nc
nc
‘B’ Mono Mic Input
1
2
3
4
5
6
7
8
(+) in
(-) in
nc
Ground
Stop Logic
nc
Logic common
Start Logic
‘A Mono Mic Input
1) Mono Mic Input module (MARC-MIC)
1
2
3
4
5
6
7
8
Talk
Tally
Channel Off
Ground
Channel On
Cough
nc
nc
Logic
1
2
3
4
5
6
7
8
Left (+) in
Left (-) in
Right (+) in
Ground
nc
Right (-) in
nc
nc
‘B’ Stereo Line Input
1
2
3
4
5
6
7
8
Left (+) in
Left (-) in
Right (+) in
Ground
Stop Logic
Right (-) in
Logic common
Start Logic
‘A Stereo Line Input
2) Stereo Line Input module (MARC-STL)
1
2
3
4
5
6
7
8
Talk
Tally
Channel Off
Ground
Stop Logic
Channel On
Logic common
Start Logic
Logic
1
2
3
4
5
6
7
8
(+) out
(-) out
nc
Ground
nc
nc
nc
nc
Phone module out
1
2
3
4
5
6
7
8
(+) in
(-) in
nc
Ground
Stop Logic
nc
Logic common
Start Logic
Phone module In
3) Phone Input module (MARC-PHN)
1
2
3
4
5
6
7
8
Record Logic
Ch On-off logic
Ground
Ground
nc
nc
nc
nc
RS232 Logic
1
2
3
4
5
6
7
8
Left (+) in
Left (-) in
Right (+) in
Ground
nc
Right (-) in
nc
nc
Record Input
USB Connector
4) PC USB module (MARC-USB)
USB NOTE:
The RJ45 connec-
tor titled ‘RS232
Logic’ wires to a 9
pin RS232 D-sub
connector as illus-
trated at the right
9 Pin RS232
1 nc
2 Pin 1 RJ45
3 nc
4 nc
5 nc
6 Pin 2 RJ45
7 nc
8 nc
9 Pin 3 RJ45
PHONE MODULE NOTE:
The logic controls (1) Stop Logic,
(2) Start Logic, and (3) Logic com-
mon are momentary closures from
a dry contact reed relay (max cur-
rent = 50 milliamps). They are
avaliable on the ‘Phone module in’
and ‘Logic’ connectors for connec-
tion to the hybrid.
Start logic
Common
Stop Logic
MIC & STEREO LINE MODULES
Channel Control Logic (Turrets)
The pins on the ‘Logic’ connector
are used to remote control the
module for applications such as
studio talk turrets. Controls include
Channel On, Off, Tally LED driver
for on-off status, Talk to Console,
and momentary Cough logic. All
control is by dry closure to ground.
The tally LED should be connected
through a 510 ohm resistor to
ground.
Start logic
Common
Stop Logic
Channel On
Channel Off
On-off Tally LED
Talk to Console
Cough
Ground
Source Control Logic
The logic controls (1) Stop Logic, (2)
Start Logic, and (3) Logic common are
momentary closures from a dry con-
tact reed relay (max current = 50
milliamps). They are available for start
and stopping source devices like CD
players
INPUT OUTPUT WIRING SUMMARY
Page view 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 81 82