Arrakis Systems X-mixer-14-22 Specifications Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 29
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
THE X-MIXER DIGITAL CONSOLE
10
MISCELLANEOUS
LOGIC CONNECTIONS
Warning Lamp
All logic outputs for the console are high
current open collector logic sinks to ground.
This type of logic output can directly con-
nect to many peripheral devices without an
interface. The open collector logic can sink
up to 50 milliamps and a maximum of 12
VDC.
If the warning light control logic requires
higher voltages or currents than the console
open collector logic is rated, an interface cir-
cuit is required. Examples would be a pow-
ered mechanical relay, solid state relay, or
optoisolator. The circuit on this page illus-
trates how to use the console logic output to
drive an external relay.
NOTE: do NOT use the console muting
logic to directly switch the AC line voltage
to the lamp.
+12VDC
Logic
Output
(maximum
12VDC, 50mA)
Ground
Warning Lamp Interface Connections
Note: Do not use the console muting logic to directly
switch the AC line voltage to the lamp
+5
VDC
Relay
+
-
Control Room
Warning Lamp
Pin Signal Description
1 Out #1, 500mA ground sink
2 Out #2, 500mA ground sink
3 Out #3, 500mA ground sink
4 Out #4, 500mA ground sink
5 Audio & Logic ground
6 Shield Ground
7 Out #5, 500mA ground sink
8 Out #6, 500mA ground sink
9 CR Mute, 500mA ground sink
Miscellaneous Logic Output
open collector darlington to ground
(9-pin connector signals)
+5
VDC
Power
Supply
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 28 29